Loading...
HomeMy WebLinkAboutOrdinance 0516 ORDINANCE NO. 516 BE IT ORDAINED by the City Council of the City of North Richland Hills, Texas, that Ordinance No. 351, adopted November 8,1971, adopting Rules, Regulations, Policies, and Procedures for the City of North Richland Hills Water and Sewer System, be amended so that the following amendments to the said Rules, Regulations, Policies and Procedures be and they are hereby made as follows: I. Section 4.3 of the Appendix Section "C", City Standard Construction Specifications for Water Distribution System on page 63 shall be deleted, both as originally approved and as amended on October 23, 1972, and the following shall be substituted therefor: "4.3 Asbestos Cement Pipe shall conform to AWWA C400-64T as herein excepted or further clarified. An affidavit of compliance shall be furnished in accordance with Section 5 of AWWA standard. Pipe class shall be for a working pressure not less than 200 p.s.i. for 6" pipe and be in standard 10 ft. or 13 ft. lengths. 8" and larger pipe shall be for a working pressure not less than 150 p.s.i. and be in standard 13 ft. lengths with 10% permissible shorter random lengths allowed as per AWWA standards. Asbestos-cement pipe couplings shall include an asbestos-cement sleeve, of the same composition as the pipe, and two rubber rings. The couplings shall be machined so as to insure a tight joint with the pipe. The rubber rings used to seal the joints shall conform to the requirements of the latest revision of ASTM D 1869." II. Sub-section "C, 1 & 2" of Section VI, System Extensions to serve Subdivison Developments, on pages 26 and 27 shall be deleted, and the following shall be substituted therefor: "C. Evaluated Prices When the City participates in the cost of facilities for oversizing or for any other reason, separate bid items shall be set up to reflect the cost to the City when such separate items can be feasibly determined. In the absence of such specific bid prices, the price shall be determinded by using a current bid price or city engineer's estimated price. II III. Sub-section "C-7" of Section VII, Standard Requirements and Criteria of Design for System Extensions -- In addition to Sewage System Design and Construction Standards, on page 32, the following material and specifications may be used: IIGravity flow sewer pipe of size twelve (12") inches and smaller shall be unplasticized polyvinyl chloride (PVC) Plastic Gravity Sewer Pipe with integral wall bell and spigot joints for the conveyance of domestic sewage. Pipe and fittings shall meet the strength requirements of ASTM specification D 3034, SDR 35. (SDR is arrived at by dividing the pipe o. d. by wall thickness.) Joints for the PVC pipe and fittings shall be compression rubber gasket joints. The bell shall consist of an integral wall section stiffened with two PVC retainer rings which securely lock the solid cross section rubber ring into position. Fittings and accessories shall be manufactured and furnished by the pipe supplier or approved equal and have bell and/or spigot configuration identical to that of the pipe. Minimum pipe stiffness at 5% deflection shall be 46 for all sizes when calculated in accordance with ASTM D-2412. Pipe Size Outside Diameter Minimum Wall Thickness 411 611 811 1011 12" 4.215" ± 0.007 6.275 ± 0.009 8.400 ± 0.010 1 O. 500 ± 0.013 12.500 ± 0.016 O. 125 O. 180 0.240 0.300 0.360 Deflection of PVC Pipe: The maximum allowable initial deflection is 10% with a maximum of 50% of the initial deflection allowable within the first 10 years. 11 PASSED AND APPROVED this 28th day of January, 1974. ATTEST: ~c4u&~ Anna Lee Caudry, City Secretary APPROVED AS TO FORM AND LEGALITY: ~/. ~ . ~~~~- 'i-im Trüman :--ríty "Aftòrney